The HPE StoreFabric SN2100M is a high-density, half-width 100 Gigabit Ethernet switch designed for enterprise storage fabric and data center networking. It provides 16 QSFP28 ports supporting 100GbE connectivity with a total switching capacity of 1.6 Tbps and forwarding rate of 2.38 Bpps, enabling non-blocking, wire-speed performance across all ports simultaneously. The switch supports flexible port configurations through QSFP28 breakout cables, allowing up to 64 sub-ports in x4 mode or 32 sub-ports in x2 mode for mixed-speed deployments. Built on Mellanox Spectrum ASIC architecture, it delivers ultra-low latency with true cut-through forwarding, zero packet loss performance, and native RoCEv2 RDMA support for converged storage and compute environments. Advanced Layer 2 and Layer 3 features include VLAN trunking, LACP, STP/RSTP, IPv4/v6 routing with OSPF and BGP, VRF, ECMP, and PTP boundary clock functionality. The SN2100M is optimized for power efficiency with less than 6 watts per port, reducing operational costs while maintaining enterprise-grade reliability. Ideal for primary and secondary storage deployments, hyperconverged infrastructures, and high-performance computing environments requiring deterministic, low-latency fabric connectivity.
| Manufacturer part # | P11673-001 |
|---|---|
| Brand | HPE |
| Condition | New |
| Cooling | Front-to-back or back-to-front airflow; optimized for low heat generation |
| Model Name | SN2100M |
| Device Type | 16-Port Network Switch |
| Product Line | StoreFabric M-series |
| Product Type | 100 Gigabit Ethernet Switch |
| RoCEv2 Support | Native Layer 2 and Layer 3 RDMA over Converged Ethernet v2 |
| Layer 2 Features | STP (IEEE 802.1d), RSTP (IEEE 802.1w), PVRST, PVST, bridge assurance, BPDU guard/filter, VLANs, VLAN trunks (802.1q), LACP (802.3ad), LACP bypass, storm control, LLDP, CDP, IPv6 neighbor discovery, IPv6 route advertisement |
The SN2100M integrates seamlessly into HPE StoreFabric M-series environments and supports open networking with Cumulus Linux or proprietary ONYX OS. It is compatible with standard 100GbE QSFP28 optics, breakout cables for mixed-speed deployments, and enterprise server NICs. Management is via standard RJ45 Ethernet or RS232 serial console. Power and cooling are configurable for various data center environments.
Can be deployed side-by-side with other SN2100M units for increased port density in 1RU space.
Compatible in multi-tier fabric architectures; SN2100M typically used as ToR, SN2700M as spine.
Lower-speed alternative with 18x 25GbE SFP28 + 4x 100GbE QSFP28 ports for mixed-speed deployments.
Primary and secondary storage array interconnect with RoCEv2 RDMA for NVMe over Fabrics and iSER protocols.
Details
Shipping, warranty & returns
No reviews yet — be the first to review this part.
Secure SSL checkout. Visa, Mastercard, Amex and Discover accepted. ACH / wire available for businesses.
New, certified-refreshed and OEM stock with guaranteed compatibility, backed by warranty on every part.
We process quotes, POs, stock documentation and compliance invoicing.
[email protected]| Layer 3 Features |
|---|
| IPv4/v6 routing, OSPFv2, OSPFv3, BGPv4/v6, VRF with route leaking, ECMP with resilient hashing, BFD, policy-based routing, GRE tunneling, PTP boundary clock, VNI scaling (6 bridges, up to 1,000 VNIs), GTP hashing, adaptive routing with RoCEv2 |
| ASIC Architecture | Mellanox Spectrum-1 (25GbE NRZ encoding capable) |
|---|
| Multicast Support | Protocol-independent multicast (PIM, PIM-SM, PIM-SSM) |
|---|
| Part Number (MPN) | P11673-001 |
|---|
| Typical Use Cases | Storage fabric, data center spine/core, HPC networking, hyperconverged infrastructure, database acceleration, cloud data centers |
|---|
| Transceiver Support | 100GBASE-SR4 (70m), 100GBASE-LR4 (10km), 100GBASE-ER4 (40km), 100GBASE-CWDM4 (2km) |
|---|
| Compliance Standards | TAA-compliant (Trade Agreements Act) |
|---|
| Deployment Scenarios | Top-of-rack (ToR) leaf switch, spine/core layer, primary/secondary storage interconnect, converged storage-compute fabric |
|---|
| Quality of Service (QoS) | PFC (Priority Flow Control), DCBX, ECN, zero packet loss for NVMe TCP and RoCEv2 |
|---|
| Latency | Ultra-low cut-through forwarding |
|---|---|
| Forwarding Rate | 2.38 Bpps (billion packets per second) |
| Packet Buffering | 16 MB fully-shared |
| Switching Capacity | 1.6 Tbps full-duplex |
| Power Supply | Redundant hot-swappable AC or DC power modules (configuration-dependent) |
|---|---|
| Power Consumption | Less than 6 watts per port; specific total wattage depends on configuration and port utilization |
| Form Factor | Half-width 1RU (can be deployed side-by-side with another SN2100M in 1RU) |
|---|---|
| Airflow Direction | Configurable: Power-to-Connector (P2C) or Connector-to-Power (C2P) |
| System Status Indicators | System, Fan, Power Supply, Unit Identifier LEDs |
| Humidity | 5% to 95% non-condensing |
|---|---|
| Storage Temperature | -40°C to 70°C (-40°F to 158°F) |
| Operating Temperature | 0°C to 40°C (32°F to 104°F) |
| Port Configuration | 16x 100GbE QSFP28 ports |
|---|---|
| Management Interface | 1x RJ45 Ethernet (1Gbps) front, 1x RS232 serial console (115200 baud), 1x USB 2.0 Mini |
| Port Breakout Support | x4 mode (64 sub-ports at 25GbE) or x2 mode (32 sub-ports at 50GbE) |
High-speed spine/core layer switch for large-scale data center networks requiring 100GbE uplink capacity.
High-performance computing cluster interconnect with low-latency, zero-loss forwarding for scientific computing.
Converged storage and compute fabric for HCI platforms combining storage, compute, and networking.
Low-latency interconnect for in-memory databases and real-time analytics requiring deterministic performance.
Tenant isolation and east-west traffic optimization in multi-tenant cloud environments.
The HPE StoreFabric SN2100M delivers 1.6 Tbps full-duplex switching capacity with a forwarding rate of 2.38 Bpps (billion packets per second). This non-blocking architecture ensures all 16 ports can operate at full 100GbE line rate simultaneously without congestion, making it ideal for demanding storage fabric and data center spine applications requiring deterministic performance.
Yes, all 16 QSFP28 ports support split x4 or x2 mode using breakout cables. In x4 mode, you can achieve up to 64 sub-ports at 25GbE each; in x2 mode, up to 32 sub-ports at 50GbE each. This flexibility allows you to mix 100GbE uplinks with lower-speed access ports in the same switch for cost-optimized, multi-tier fabric designs.
The SN2100M offers native RoCEv2 (RDMA over Converged Ethernet v2) support at both Layer 2 and Layer 3, enabling zero-copy, low-latency remote memory access for NVMe over Fabrics, iSER, and other RDMA-accelerated protocols. It includes full PFC (Priority Flow Control), DCBX, and ECN support for lossless Ethernet, critical for storage and HPC workloads.
The SN2100M supports comprehensive IPv4/v6 routing including OSPFv2, OSPFv3, BGPv4/v6, VRF with route leaking, ECMP with resilient hashing, BFD, policy-based routing, GRE tunneling, and PTP boundary clock. These features enable it to function as a spine switch in large-scale, multi-tier data center networks with advanced traffic engineering.
The SN2100M provides 16x 100GbE QSFP28 ports (1.6Tbps capacity), while the SN2700M offers 32x 100GbE QSFP28 ports (6.4Tbps capacity). The SN2100M is a half-width switch ideal for top-of-rack and smaller fabric deployments, whereas the SN2700M is a full-width switch for larger spine/core roles requiring higher port density and throughput.
The SN2100M is designed for ultra-low power consumption at less than 6 watts per port, significantly reducing operational expenses and heat generation compared to competing switches. This efficiency, combined with its compact half-width form factor, allows for higher density deployments in power-constrained data center environments while maintaining enterprise reliability.
The SN2100M includes 16 MB of fully-shared packet buffering and delivers true cut-through forwarding with ultra-low latency, enabling zero-packet-loss performance for NVMe TCP and RoCEv2 RDMA workloads. This combination of ample buffer and minimal latency is critical for storage fabric and HPC applications where predictable, deterministic performance is essential.
You might also want to check out these products.

Cisco Meraki MS125-48LP-HW

Cisco Meraki MS125-48LP

AT-8624T/2M - Allied Telesis 8600 24-Port 2x Module Bays uplink Switch

AT-9000/24 - Allied Telesis 9000/52-10 24-Port Switch

469-3414 - Dell PowerConnect 5524 24-Port + 2 x SFP+ Ports 1U Switch

AT-GS910/24-50 - Allied Telesis CentreCOM GS910 24-Ports Switch

AT-FS717FC/SC-10 - Allied Telesis 16x 1x 100BFX SC Connector Switch

AT-9424T/SP - Allied Telesis 9400 24-Port 2x Port SFP Switch