MPN: 342-2017·By: Dell
Ships from the US.
Order by 1:00 PM CST for overnight shipping
Buying in volume or need a PO?
Have a target price for 342-2017? Call +1 (551) 421-5162 or request a bulk quote and our sales team will reply within one business day.
EN 342:2017 is a European standard that specifies performance requirements and test methods for clothing ensembles and garments designed to protect against cold environments with temperatures equal to or below -5°C. The standard addresses the combined effects of low air temperatures, humidity, and wind speed on worker safety and comfort. It applies to complete clothing systems such as two-piece suits and one-piece coveralls. Key performance parameters include resultant basic thermal insulation measured as Icler with a minimum value of 0.265 m²·K/W, air permeability, and optional water permeability testing. The standard excludes protective functions of footwear, gloves, and separate headgear, which are covered under separate standards. EN 342:2017 ensures reliable protection through defined material quality, design specifications, and functional details that maintain practicality in demanding work environments.
| Manufacturer part # | 342-2017 |
|---|---|
| Brand | Dell |
| Condition | New |
| Product Type | Protective clothing ensembles and garments for cold environments |
| Garment Types | Two-piece suits; one-piece suits; coveralls |
| Tear Strength | ≥ 20 N |
| Burst Strength | ≥ 100 kPa |
| Air Permeability | AP classes defined |
| Previous Version | EN 342:2004 |
| Standard Version | 2017 |
| Calculation Model | parallel calculation model |
EN 342:2017 applies to work in ambient temperatures of -5°C or lower, where thermal insulation and protection against wind and humidity are critical for worker safety and performance.
Two-piece suits and coveralls meeting EN 342:2017 requirements provide standardized protection for industrial workers exposed to cold, ensuring consistent performance across clothing systems.
The standard addresses combined effects of low air temperature, humidity, and wind speed, making it essential for outdoor work requiring reliable cold-weather protective clothing.
EN 342:2017 includes optional water permeability testing to ensure protection in demanding environments where moisture exposure compounds cold-related risks.
EN 342:2017 specifies a minimum thermal insulation value of 0.265 m²·K/W, measured as Icler. Higher Icler values indicate superior insulation performance. This baseline ensures all compliant clothing systems provide adequate heat retention in cold environments at or below -5°C.
Details
Shipping, warranty & returns
No reviews yet — be the first to review this part.
Secure SSL checkout. Visa, Mastercard, Amex and Discover accepted. ACH / wire available for businesses.
New, certified-refreshed and OEM stock with guaranteed compatibility, backed by warranty on every part.
We process quotes, POs, stock documentation and compliance invoicing.
[email protected]| Minimum Insulation | 0.265 m²·K/W |
|---|
| Pocket Requirement | outer pockets must be lockable |
|---|
| Water Permeability | WP (optional) |
|---|
| Closure Requirement | closable up to the collar or neckband |
|---|
| Protection Category | Category II |
|---|
| Surface Requirement | no sharp or distracting surfaces |
|---|
| Test Method Thermal | EN ISO 15831:2004 |
|---|
| Related Cool Standard | EN 14058 |
|---|
| Reference Undergarment | C |
|---|
| Temperature Protection | ≤ -5 °C |
|---|
| Thermal Insulation Icler | Minimum 0.265 m²K/W |
|---|
| Jacket Length Requirement | must cover the waistband of trousers |
|---|
EN 342:2017 applies to cold environments with ambient temperatures equal to or below -5°C. The standard accounts for combined effects of low air temperature, humidity, and wind speed, ensuring protection under realistic field conditions rather than temperature alone.
EN 342:2017 specifies requirements for complete clothing systems including two-piece suits and one-piece coveralls. The standard excludes protective functions of footwear, gloves, and separate headgear, which are covered under separate standards like EN 14058.
EN 342:2017 requires testing of thermal insulation and air permeability as mandatory parameters. Water permeability testing is optional, allowing procurement teams to specify enhanced protection for high-humidity or wet cold environments based on specific workplace hazards.
EN 342:2017 covers protective clothing ensembles for cold environments below -5°C, while EN 14058 specifies requirements for garments protecting against cool environments. EN 342:2017 excludes footwear, gloves, and separate headgear, which have their own protective standards.
Water permeability is optional because not all cold work environments involve significant moisture exposure. This flexibility allows procurement teams to specify baseline cold protection for dry conditions or enhanced protection with water resistance for high-humidity or wet cold environments.
You might also want to check out these products.

MG1NG - Dell EMC 16TB 7.2K RPM SAS 12Gbps 512e 3.5-in HDD W/ Tray

ST3000NXCLAR3000 - Data Domain 3TB 7200 RPM SAS 3.5-Inch Hard Drive

27X0400 - Lexmark 320GB SATA 6Gb/s 2.5-Inch Hard Drive

TY36J461 - Quantum 36GB 10000RPM SCSI 160MB/s 3.5-in Hard Drive

SDSSDE81-2T00-G25 - SanDisk 2TB USB 3.2 Gen 2 Type-C Portable SSD

S26361-H846-V100 - Siemens 146GB 10000RPM SCSI 320MB/s 3.5-in HDD

S3610 - Intel 1.2TB SAS 10000RPM 2.5-Inch Hard Drive

306-1198-00 - Symantec 1TB 7200RPM SAS 6Gbps 3.5-in Hard Drive